Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 96

96
K2 Storage Area Network Installation and Service Manual
26 October 2009
Chapter 4 Setting up K2 SAN infrastructure
9. Click
Modify Selected Ports
.
10.Make sure Port Enabled is set to
Yes
, leave Mode as default of
Auto
.
11.Set Flow Control as follows:
• Set to
Disable
.
12.Click
Apply Settings
. Wait until settings are applied and the Web interface
becomes active.
13.Proceed as follows:
• If the switch carries no media (iSCSI) traffic, such as for a Nearline system,
there is no need to configure VLANs. Skip to the end of this procedure.
• If the switch carries media (iSCSI) traffic, then it must have VLANs configured.
Continue with the next step in this procedure.
14.Choose
VLAN Configuration
. If prompted, log in with the switch’s administrator
username and password.