Connect the iSCSI interface port to a media port on the GigE switch. Connect
the A server to the A GigE switch. Connect the B server to the B GigE switch.

Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch. Connect the A server to the A GigE switch. Connect the B server
to the B GigE switch.

Connect the Fibre Channel port to the RAID storage device. Connect the A
server to controller 0 and the B server to controller 1.

Make a direct connection between the serial ports of the two servers.

Take care to use the proper serial cable to interconnect redundant K2 Media
Servers. This cable supports the heartbeat mechanism whereby the servers
monitor each other’s health. It is a 9 pin serial cable, but it is not a standard
RS-232 null modem cable. The heartbeat cable is supplied with your system
(Grass Valley part number 174-8137-00). Refer to the K2 client System Guide
for pinout details.