Configuring server 1a - part 2 – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 310

26 October 2009
K2 Storage Area Network Installation and Service Manual
310
Configuring server 1A - Part 2
iSCSI Bridge Server
Configuration
This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
RANKs are visible as iSCSI
targets.
Select
Primary
.
Select an iSCSI adapter and click
Modify
. A network configuration
dialog box opens. Verify or enter the media network IP address and the
subnet mask and click
Apply
. Do the same for the other iSCSI adapters.
Click
Check
. The Validation Report opens.
Confirm that the iSCSI configuration is successful. Close the Validation
Report and then click
Next
.
Metadata Server
Configuration
Enter the name or IP address of K2 Media server 1B. This is the
redundant partner of the server you are now configuring.
Click
Next
.
On this page…