Powering on the hp procurve switch, Powering on the control point pc, Ftp on k2 sans – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 363

363
K2 Storage Area Network Installation and Service Manual
26 October 2009
Chapter 9 Operating the K2 SAN
Powering on Level 10, 20, 30, and Nearline 10 RAID storage
devices
Use the following procedure to power on and verify proper operation of RAID storage
devices.
Powering on the HP ProCurve switch
Use the following procedure to power on and verify proper operation of the HP
ProCurve switch.
1. Power up the switch.
2. Watch LEDs to verify proper operation. The diagnostic self test LED Behavior is
as follows:
• Initially, all the status, LED Mode and port LEDs are on for most of the duration
of the test.
• Most of the LEDs go off and then may come on again during phases of the self
test. For the duration of the self test, the Test LED stays on.
If the ports are connected to active network devices, the LEDs behave according to
the LED Mode selected. In the default view mode (Link), the LEDs should be on.
• If the ports are connected to active network devices, the LEDs behave according
to the LED Mode selected. In the default view mode (Link), the LEDs should be
on.
• If the ports are not connected to active network devices, the LEDs will stay off.
Powering on the control point PC
Use the following procedure to power on K2 SAN’s control point PC and verify
proper operation during power up of the system.
1. Power up and log on to the PC using standard Windows procedures.
2. Start and log on to NetCentral.
3. NetCentral reports devices as offline. As each device of the K2 SAN is powered
on, check NetCentral to verify the device’s status
FTP on K2 SANs
Refer to the K2 System Guide for FTP information.