Chapter 3 cabling k2 san devices – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 68

68
K2 Storage Area Network Installation and Service Manual
26 October 2009
Chapter 3 Cabling K2 SAN devices
Two GS K2 Media Servers – Dell R610 PowerEdge – redundant
Connect the two iSCSI interface ports to media ports on the GigE switch.
Connect the A server to the A GigE switch. Connect the B server to the B GigE
switch.
Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch. Connect the A server to the A GigE switch. Connect the B server
to the B GigE switch.
Connect the Fibre Channel port to the RAID storage device. Connect the A
server to controller 0 and the B server to controller 1.
Make a direct connection between the serial ports of the two servers.
Take care to use the proper serial cable to interconnect redundant K2 Media
Servers. This cable supports the heartbeat mechanism whereby the servers
monitor each other’s health. It is a 9 pin serial cable, but it is not a standard
RS-232 null modem cable. The heartbeat cable is supplied with your system
(Grass Valley part number 174-8137-00). Refer to the K2 System Guide for
pinout details.
A
B
To media (iSCSI)
ports on GigE switch A
Fibre Channel
to RAID controller 0
To media (iSCSI)
ports on GigE switch B
Fibre Channel
to RAID controller 1
To control port
on GigE switch A
FTP: To control port
on GigE switch A
To control port
on GigE switch B
FTP: To control port
on GigE switch B
Heartbeat
cable
(serial)