Adding k2 clients to the k2 san, Configuring a k2 client for the k2 storage system – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 346

26 October 2009
K2 Storage Area Network Installation and Service Manual
346
Adding K2 clients to the K2 SAN
Installing the Multi-Path Device Driver...
Success
Restarting all SCSI adapters...
Success (but need a reboot)
7. Restart the K2 client.
8. After restart, to verify that the software is installed, on the Windows desktop
right-click
My Computer
and select
Manage
. The Computer Management window
opens.
9. In the left pane select
Device Manager
.
10.In the right pane open the
System devices
node and verify that
GVG ISCSI
Multi-Path Device Specific Module
is listed.
Adding K2 clients to the K2 SAN
For each of your K2 clients, use the procedures in this section to configure for
operation using the K2 SAN as the shared media storage.
Before beginning with these procedures, make sure the K2 SAN and the K2 clients
are prepared. Cabling must be complete, K2 clients must be communicating on the
control network, and the K2 SAN must have a viable media file system.
Configuring a K2 client for the K2 Storage System
Configure a K2 client as follows:
1. On the K2 configuration control point PC, open the K2 System Configuration