Level 10, 20, 30, 35 system power-on procedure, Chapter 9 operating the k2 san – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 359

359
K2 Storage Area Network Installation and Service Manual
26 October 2009
Chapter 9 Operating the K2 SAN
Level 10, 20, 30, 35 system power-on procedure
Power on K2 SAN
Power on and verify
control point PC
.
Refer to
page 363
for procedures.
Power on and verify
HP ProCurve switches
.
Refer to
page 363
for procedures.
Power on and verify
RAID devices
.
Refer to
page 363
for procedures.
Elapsed time: 5 minutes
Elapsed time: 1 minute
Power on file system/
metadata
K2 Media
Server
.
From the control point PC, at the
command prompt, ping the K2
Media Server.
Power on
K2 clients
and
other
iSCSI clients
.
No
Yes
K2
Media Server
responds to ping?
Elapsed time:
3 minutes
Begin FTP operations.
Begin record/play operations.
K2 SAN power-on
complete
.
Power on remaining
K2 Media Servers
.
From the control point PC, at the
command prompt, ping the K2
Media Servers.
No
Yes
K2
Media Servers
respond to ping?
Elapsed time:
3 minutes