Chapter 3 cabling k2 san devices – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 70

70
K2 Storage Area Network Installation and Service Manual
26 October 2009
Chapter 3 Cabling K2 SAN devices
Two LS K2 Media Servers – Dell 2950 PowerEdge – redundant
Two LS K2 Media Servers – Dell R710 PowerEdge – redundant
Connect the four iSCSI interface ports to media ports on the GigE switch.
Connect the A server to the A GigE switch. Connect the B server to the B GigE
switch.
Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch. Connect the A server to the A GigE switch. Connect the B server
to the B GigE switch.
Connect the Fibre Channel port to the RAID storage device. Connect the A
server to controller 0 and the B server to controller 1.
PCI 1
PCI 2
PCI 3
Gb 1
Gb 2
PCI 1
PCI 2
PCI 3
Gb 1
Gb 2
A
B
To media (iSCSI)
ports on GigE switch A
Fibre Channel
to RAID controller 0
To media (iSCSI)
ports on GigE switch B
Fibre Channel
to RAID controller 1
To control port
on GigE switch A
FTP: To control port
on GigE switch A
To control port
on GigE switch B
FTP: To control port
on GigE switch B
Heartbeat
cable
(serial)
A
B
To media (iSCSI)
ports on GigE switch A
Fibre Channel
to RAID controller 0
To media (iSCSI)
ports on GigE switch B
Fibre Channel
to RAID controller 1
To control port
on GigE switch A
FTP: To control port
on GigE switch A
To control port
on GigE switch B
FTP: To control port
on GigE switch B
Heartbeat
cable