beautypg.com

Chapter 3 cabling k2 san devices – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual

Page 70

background image

70

K2 Storage Area Network Installation and Service Manual

26 October 2009

Chapter 3 Cabling K2 SAN devices

Two LS K2 Media Servers – Dell 2950 PowerEdge – redundant

Two LS K2 Media Servers – Dell R710 PowerEdge – redundant

Connect the four iSCSI interface ports to media ports on the GigE switch.
Connect the A server to the A GigE switch. Connect the B server to the B GigE
switch.

Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch. Connect the A server to the A GigE switch. Connect the B server
to the B GigE switch.

Connect the Fibre Channel port to the RAID storage device. Connect the A
server to controller 0 and the B server to controller 1.

PCI 1

PCI 2

PCI 3

Gb 1

Gb 2

PCI 1

PCI 2

PCI 3

Gb 1

Gb 2

A

B

To media (iSCSI)
ports on GigE switch A

Fibre Channel
to RAID controller 0

To media (iSCSI)
ports on GigE switch B

Fibre Channel
to RAID controller 1

To control port
on GigE switch A

FTP: To control port
on GigE switch A

To control port
on GigE switch B

FTP: To control port
on GigE switch B

Heartbeat

cable

(serial)

A

B

To media (iSCSI)
ports on GigE switch A

Fibre Channel
to RAID controller 0

To media (iSCSI)
ports on GigE switch B

Fibre Channel
to RAID controller 1

To control port
on GigE switch A

FTP: To control port
on GigE switch A

To control port
on GigE switch B

FTP: To control port
on GigE switch B

Heartbeat

cable

(serial)

This manual is related to the following products: