Level 10r, 20r, 30r, 35r system power-on procedure – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual
Page 360

26 October 2009
K2 Storage Area Network Installation and Service Manual
360
Level 10R, 20R, 30R, 35R system power-on procedure
Level 10R, 20R, 30R, 35R system power-on procedure
Power on K2 SAN
Power on and verify
control point PC
.
Refer to
page 363
for procedures.
Power on and verify
HP ProCurve switches
.
Refer to
page 363
for procedures.
Power on and verify
RAID devices
.
Refer to
page 363
for procedures.
Elapsed time: 5 minutes
Elapsed time: 1 minute
Power on the K2 Media
Server that you want to be
primary. For 7.x SAN, it is
not required that this be the
server that was primary
when you last powered down
the K2 Storage System.
From the control
point PC, in the K2
System
Configuration
application, open
Server Control
Panel
.
Put the K2 Media Server into service:
In Server Control Panel, click
Start
.
No
In Server Control Panel,
check all indicators.
Yes
No
Yes
Green
indicator?
Elapsed time:
30 seconds
In Server
Control Panel,
check the file
system server
indicator.
Green
indicators?
Elapsed time:
10 seconds
Continue with next page of power-on procedure