beautypg.com

Expanding the media file system by bandwidth – Grass Valley K2 Summit Storage Area Network v.7.1 User Manual

Page 446

background image

26 October 2009

K2 Storage Area Network Installation and Service Manual

446

Expanding the media file system by bandwidth

Verify versions of controller

microcode and disk firmware.
Update if necessary.

Refer to K2 Release Notes and

“Checking controller microcode” on
page 451

Make sure that versions are compatible on
both new and existing disks and RAID
storage devices.

Bind RANKs using the new disks.

Wait for the binding process to
complete.

“About full/background bind” on
page 455

Do not unbind or bind existing RANKs.
Doing so destroys all data. If in doubt, flash
drive lights to identify disks.

Close Storage Utility.

Restart the primary K2 Media

Server.

Do not use the standard startup
processes here. Just start up the
server and wait until the Windows
desktop appears. On a redundant K2
SAN, do not use Server Control
Panel or manually start.

Check the Windows Device Manager to
verify that the server “sees” both the old
RANKs and the new RANKs.

Start up all remaining K2 Media

Servers that are connected to the
K2 SAN.

Do not use the standard startup
processes here. Just start up the
server(s) and wait until the Windows
desktop appears. On a redundant K2
SAN, do not use Server Control
Panel or manually start.

Configure media file system

If Aurora media is present,

modify VolumeConfig.xml.

“Bandwidth expansion for Aurora

products” on page 447

From the control point PC, open

the K2 System Configuration
application and launch Storage
Utility.

“Accessing Storage Utility” on
page 437

In Storage Utility make sure both old
RANKs and new RANKs are displayed.

Using Storage Utility, expand

the file system by bandwidth.

1. Select

Tools | Expand File

System By Bandwidth

and

answer

Yes

to confirm.

A dialog box opens, asking if you
want to restripe existing media
after bandwidth expansion.

2. Click

Yes

to restripe media,

No

to skip restriping.

The first of a series of
informational screens opens.

3. Work through the

informational screens .

4. The expansion process runs.

A dialog box displays
progress.
The expansion process runs.
A dialog box displays
progress.

5. Wait for the process to

complete. On a large system
this can take over 30 minutes.

6. A “…succeeded…” message

is displayed when done. Click

OK

and Storage Utility closes.

7. The K2 System Configuration

application displays a
message informing you to
restart servers. Click

OK

.

When asked about restriping existing
media, the typical response is to click Yes.
In any case this does no harm. Click No
only if you are sure you do not need to
restripe existing media, such as in the
following cases:

You have very little existing media
so the fact that it cannot use the new
stripe group does not impact future
media operations or capacity.

Your existing media is to be deleted
soon so you don’t care if it uses the
new stripe group.

When prompted to retry, if you are not sure
if the process started, you can retry to be
sure. Doing so does not cause problems.

Make sure Storage Utility is closed before
proceeding.

Task

Documentation

Tips

This manual is related to the following products: