beautypg.com

Extraction result panel – Kofax Getting Started with Ascent Xtrata Pro User Manual

Page 291

background image

Chapter 6

272

Ascent Xtrata Pro User's Guide

To assign another locator method, click the Locator Method column and select the
method from the list.

The Comments column displays system messages. For example, if you select the
Database Locator method, “No database selected” will appear in the Comments
column until you set up the database.

Extraction Result Panel

Use this panel to show the extraction results for the current test document. The class
for which the document was extracted is shown in the toolbar.

Figure 6-8. Extraction Results Panel

Field List

This table shows all fields in the class for which the test document was extracted. The
icon shown in front of the field name indicates the state of the extraction results. A
green check mark ( ) indicates a valid field, and a blue question mark indicates an
invalid ( ) field.

Criteria for a valid or invalid state include:

• Minimum confidence value
• Distance to next candidate
• Result of field formatter
• Result of validation rules

The Content column contains the extracted field content, or for table fields, a table
icon ( ). To see the extracted content for a table field, double-click the row. The table
displays in the View Table for Field dialog box.

The Confidence column shows the confidence values for the extracted fields.