HP Hitachi Dynamic Link Manager Software Licenses User Manual
Page 548
Message
ID
Message Text
Explanation
Make sure that sufficient free
capacity exists for the /var/tmp
directory. If the capacity is
insufficient, allocate the required
amount of capacity, and then retry
the operation. For details about
the required free capacity, see
.
KAPL09217
-E
An error occurred during reading
of the installation information
settings file. Error Code =
aa...aa,bb...bb
Details
An error occurred while reading
the installation information
settings file.
aa...aa: Error number (decimal
number) that specifies the
executed processing
bb...bb: Return value (decimal
number) of the executed
processing
Action
If the error code is 9001,-1:
You do not have read
permissions for the installation
information settings file. Make
sure that you have access
permissions.
If any other error code is output:
Contact your HDLM vendor or
the maintenance company if
there is a maintenance
contract for HDLM.
KAPL09218
-E
aa...aa cannot be executed.
Details
A utility or command that
installhdlm uses was not in the
correct location, or you do not
have a required permission.
aa...aa: installhdlm_analysis,
dlnkmgr, or dlmsetconf
Action
If aa...aa is dlnkmgr or
dlmsetconf:
The correct location of
dlnkmgr and dlmsetconf
is /opt/
DynamicLinkManager/bin. If
dlnkmgr or dlmsetconf was
not in the correct location, or
you did not have a required
8-72
Messages
Hitachi Dynamic Link Manager (for Solaris) User Guide