If you omit the intermittent error monitoring interval or the number of
times that the error is to occur, each setting is specified as follows:
¢
When the intermittent error monitoring interval or the number of
times that the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 30 minutes, and
the number of times that the error is to occur is set to 3.
¢
When the intermittent error monitoring interval or the number of
times that the error is to occur has been specified before:
The values specified from the last time are used.
When a value of 2 or more is specified for the number of times, the
following condition must be satisfied:
error-monitoring-interval >= checking-interval-for-automatic-
failback x number-of-times-error-is-to-occur-during-intermittent-
error-monitoring
If this condition is not satisfied, the KAPL01080-W message will be output
and an error will occur. If this happens, change any of the following
settings: the checking interval for automatic failback, intermittent error
monitoring interval, or the number of times that the error is to occur.
When you set the number of times that the error is to occur to 1, the
above condition does not need to be satisfied.
The following shows the sub-parameters that should be specified: the
error monitoring interval and the number of times that the error is to
occur:
-intvl error-monitoring-interval
Specify the monitoring interval for an intermittent error. Use a value
from 1 to 1440 minutes. The default is 30.
During intermittent error monitoring, if changes are made in the
settings of the intermittent error monitoring interval, the error count
and the elapsed time measured since monitoring starts are set to 0,
and monitoring starts by using the new settings.
Outside the duration of intermittent error monitoring, if changes are
made in the settings of the intermittent error monitoring interval, the
new settings take effect after the next time automatic failback
succeeds. Outside the duration of intermittent error monitoring, the
number of errors that determine an intermittent error is not counted
and this value is not changed.
The monitoring interval specified in this parameter is stored even
though specifying -iem off disables intermittent error monitoring.
Therefore, when you re-enable intermittent error monitoring and a
monitoring interval is not specified, error monitoring will be performed
by using the stored monitoring interval.
-iemnum number-of-times-error-is-to-occur
Specify the number of times the error is to occur. Valid values are
from 1 to 99. The default is 3.