Updating device firmware

4

NOTE

The access point must complete the reboot process to successfully update the device
firmware, regardless of whether the reboot is conducted using the GUI or CLI interfaces.

10. After the AP reboots, return to the Firmware Update screen. Check the Status field to verify

whether the firmware update was successful. If an error occurs, one of the following error
messages will display:

FAIL: auto fw update check

FAIL: network activity time out

FAIL: firmware check

FAIL: exceed memory limit

FAIL: authentication

FAIL: connection time out

FAIL: control channel error

FAIL: data channel error

FAIL: channel closed unexpected

FAIL: establish data channel

FAIL: accept data channel

FAIL: user interrupted

FAIL: no valid interface found

FAIL: conflict ip address

FAIL: command exchange time out

FAIL: invalid subnet number

11. Confirm the Mobility 5181 Access Point configuration is the same as it was before the firmware

update. If they are not, restore the settings. Refer to

“Importing/exporting configurations”

on

page 81 for instructions on exporting the configuration back to the Mobility 5181 Access Point.

12. Click Apply to save the filename and filepath information entered into the Firmware Update

screen. The Apply button does not execute the firmware, only saves the update settings
entered.

13. Click Undo Changes (if necessary) to undo any changes made. Undo Changes reverts the

settings displayed on Firmware Update screen to the last saved configuration.

14. Click Logout to securely exit the Mobility 5181 Access Point applet. A prompt displays

confirming the logout before the applet is closed.