7.3 Upgrading the MVX-A16 card FPGA with Xilinx tools
To upgrade the MVX FPGA with Xilinx tools:
1. Ensure that the latest version of the Xilinx programming tools has been installed.
Tip:
For more information about installing the Xilinx programming tools, see
2. Connect the USB connector of the download cable (Platform cable USB DLC9G) to the USB
port of the PC.
3. Connect the 14way IDC header to CON12 (see Figure 46: MVX-A16 card: J1, CON).
4. Power up the MVX-A16 card and start the iMPACT programming tool.
5. In Load Project, select Cancel.
6. In Flows, double click Boundary Scan. Right click the main window and select
Initialise Chain / Ctrl+ I:
Figure 47: Example iMPACT Boundary Scan
78