5.11 Downloading a test configuration to the CPU card

using EHX

After you have upgraded your Eclipse HX-Median / Eclipse HX-Omega / Eclipse HX-Delta matrix CPU
cards, Clear-Com recommends downloading a test configuration from EHX to the CPU cards.

Downloading a configuration will enable you to make any further configuration changes to the cards
using either a serial or Ethernet connection.

For more information, see your EHX User Manual.

5.12 Forcing the CPU card to the factory default IP address


In rare situations, the CPU card may not be able to find a valid IP address for the Ethernet port. To
address this issue, you can force the matrix to the factory default IP address (169.254.0.100):

1. Set your PC Ethernet IP address to DCHP mode.

2. Directly connect the PC to the matrix, using an Ethernet crossover cable.

3. Force the system to use the default IP address, by performing the 3-finger reset. Press and

hold both the ENG and FULL RESET front panel buttons simultaneously, then press the top
RESET button.

4. When the CPU card OK LED starts to flash, release both the ENG and FULL RESET buttons.

Tip:

For help with selecting the other procedures you require for upgrading to EHX, see the quick

reference procedures tables in 3 Quick reference: Upgrading to Eclipse HX v7..

.