Clear-Com HX System Frames User Manual
Page 72
6.6 Checking the Eclipse HX-PiCo application code and
MVX code versions
You can check both the Eclipse HX-PiCo application code and MVX code versions by going to EHX>
Matrix Event Log > Matrix Overview.
You can also use the Firmware report tool in EHX to confirm code versions. To use the Firmware
report tool:
1. Go to EHX> System> Layout.
2. Right click the matrix icon.
3. Select Firmware > Firmware report.
To check the Eclipse PiCo MVX code version only using Tera Term:
1. Install Tera Term. Tera Term is available to install from both of the Eclipse HX 7.5 DVDs:
• Software DVD > 3rd_Party_Software > Teraterm
• Hardware DVD > 3rd_Party_Software > Teraterm
2. Open Tera Term and select the following port settings:
Port setting
Setting to enter
Port
COM1 (Change to match a COM port present on the PC)
Baud rate
115200
Data
8 bit
Parity
None
Stop
1 bit
Flow control
none
Table 19: Tera Term port settings
3. Open the Eclipse HX-PiCo lid.
Remove power from the devices first, to avoid working with the system while it
is live. Observe all electrical shock hazard warning and precautions for
handling electrostatic sensitive devices
65
Eclipse HX Upgrade Guide