13. To upgrade the V-Series Kernel, Root File System and Application files:
a. Press and hold down both the AUX and MAIN knobs whilst applying a reset.
The reset may be applied by either power cycling the panel or poking a paper clip into
the reset hole between the H/S and MENU buttons.
b. The 4 function button LEDs (Mic On, H/S, Shift and Menu) will flash. Press and
release the Shift button to trigger the Kernel, Root File System and Application
files upload.
Note:
As the upload proceeds, the AUX and MAIN lights on the panel will gradually change
from
green
to
amber
and then
red
. This process may take a few minutes.
c. When the upload is complete, the panel will reset itself, completing the procedure.
Wait until the panel completely resets itself and displays the offline status screen
before powering down the panel (example shown below).
Figure 107: Panel after update reset
Notes
:
After the V-Series panel has been upgraded using the TFTP server some of the level settings
may be disabled. IP settings will also be lost. To restore the level and IP settings, download a
map from EHX using the Clear Matrix Data option.
139
Eclipse HX Upgrade Guide