beautypg.com

Clear-Com HX System Frames User Manual

Page 56

background image

3. In the Matrix connection dialog, select the serial communications option.

4. Select the correct COM port then click OK.

5. Connect the PC to the serial port on the front of the device, using an RS232 cable with DB9 to

3.5mm jack connectors (CellCom / FreeSpeak (FSBP) registration cable (PD4007Z)).

6. Do one of the following:

• If you are running EHX in Client-Server mode, select File > Import project.

Navigate to the configuration ( *.ccn) file and click Open to import the file.

• If you are running EHX in Client-Only mode, select File > Open. Navigate to the

configuration (*.ccn) and open the file.

Note:

EHX can open *.ccn format files as well as its own *.hxn format configuration files.

6. In EHX, select System > Layout. In the work area, right click the matrix.

7. From the menu, select Firmware > Update Firmware.

Figure 31: Upgrading app code: Matrix firmware update

8. In the Firmware update wizard, click Next. Ensure that Matrix is selected in the following

dialog, then click Next again.

49

Eclipse HX Upgrade Guide

This manual is related to the following products: