Clear-Com HX System Frames User Manual
Page 154
2. Fit the AES-6 card to either the
IMF-3 interface frame or Eclipse HX-Median Matrix. If there is
a jumper on J6, move the jumper to J3.Reset or power-cycle the card so the jumper change
takes effect.
3. Connect the serial cable to the front of the AES-6.
4. Run Flash Development Toolkit BASIC (FDT). Configure the FDT (Options > New Settings)
as follows:
FDT field
Setting
Select Device
H8S/2318F
Select Port
COM1 (change to match COM port present on the PC)
CPU Frequency
25.0000 MHz
Connection
BOOT mode
Recommended Speed
Deselect Use Default and set to 9600
Protection
Automatic
Messaging
Advanced
User data
Selected (Checked)
Table 43: FDT settings
5. Navigate to the AES-6 application code (*.mot format file) on the software DVD:
Software DVD > Other_Software > xxxxxxZ - AES-6 Application
Where xxxxxxZ represents the product number).
6. Select Program Flash and download the AES-6 application code (*.mot format file).
7. When the download is complete, move the jumper on J3 back to J6. Reset or power-cycle the
card.
Note:
If an FPGA image is present, the card will now run normally. If an FPGA image is not present,
you will be prompted for an FPGA image. See 3.33.1 Upgrading AES-6 FPGA.
147
Eclipse HX Upgrade Guide