2. Start Tera Term.
Configure Tera Term for the appropriate COM port on the PC, as shown in the following
figure. Select the Serial radio button and then the correct COM port setting for the PC from
the Port drop-down menu. Click OK.
Figure 97: Tera Term: COM port setting
3. From the Tera Term main screen select Setup > Serial port….
The serial port setup screen should now be visible. Select the following settings to configure
Tera Term for updating the E-station:
Field
Setting
Baud
19200
Data
8 bit
Parity
None
Stop
1 bit
Flow Control
None
Table 38: Serial port setup screen settings
Note:
Do not configure (ignore) the Transmit delay settings.
Click OK.
4. Power up the E-station into maintenance mode by first holding in the recessed button found
on the rear panel during a simultaneous AC power up.
The reset button must be held in until all front panel keys turn
bright red
and the front panel
display modules show the message Display Module Test, Press All Buttons 3x.
131