To upgrade E-MADI64 H8, DSP or FPGA code using EHX:

1. Ensure that you have the following equipment:

Required equipment

Description / comments

PC with an Ethernet or serial
communications port

-

EHX software

EHX must be installed and configured.

Ethernet or serial cable for the
PC-to-matrix connection

-

H8 application code, DSP and
FPGA code files

The appropriate application code, DSP code and FPGA
code files (*.fwc format) are available from the Eclipse
HX v7.5 DVDs:

Software DVD > Eclipse HX-Omega-Median-

Delta > E-MADI Application

Software DVD > Eclipse HX-Omega-Median-

Delta > E-MADI DSP

Hardware DVD > Eclipse HX-Omega-Median-

Delta > E-MADI FPGA.

Table 33: Required equipment

2. Start EHX on the PC.

3. Connect the PC to the matrix using either Ethernet or a serial communications port.

4. Open the EHX configuration map within EHX.

5. Select System > Layout.

6. Right click the matrix and then select Firmware> Update Firmware.

The Update Firmware wizard dialog is displayed. Click Next.

In the Select Hardware Type screen, ensure that the Card radio button is selected.

Figure 81: Select Hardware Type

113

Eclipse HX Upgrade Guide