Clear-Com HX System Frames User Manual
Page 65
6.5.1 Upgrading the Eclipse HX-PiCo MVX application code
with EHX
Important note:
To upgrade the Eclipse HX-PiCo MVX application code with EHX, your system must already be
running a version of Eclipse HX.
Recommendation
Clear-Com recommends that you monitor the MVX application code upgrade using the Event Log in
EHX. The upgrade process is complete when the MVXs on the Eclipse HX-PiCo briefly disappear and
then reappear in the log. To check that the upgrade has been successful, run a firmware report.
If the upgrade is unsuccessful, use the Renesas FDT to upgrade the MVX code
(see 6.5.2 Upgrading the Eclipse HX-PiCo MVX boot and/or application code using the Renesas
FDT).
To upgrade the Eclipse HX-PiCo MVX application code using EHX:
1. Ensure that you have the following equipment:
Required equipment
Description / comments
PC with an Ethernet connector
-
Serial cable or Ethernet cable for
the PC to matrix connection
-
EHX installation
EHX must be configured and operational.
An EHX configuration file (*.hxn
or *.ccn format)
The configuration file must have an appropriate IP
address set.
The appropriate *.fwc format file
for the Eclipse HX-PiCo MVX
cards / sections
You can find the Eclipse HX-PiCo MVX application
code (*.fwc) file on the software DVD:
Software DVD > Eclipse HX-PiCo > xxxxxxZ-MVX
Application
Table 16: Required equipment
2. Start EHX on the PC.
3. Connect the PC to the matrix using either Ethernet or a serial communications port.
4. Open the EHX configuration map within EHX. Select System > Layout.
5. Right click the matrix and then select Firmware> Update Firmware.
58