beautypg.com

Clear-Com HX System Frames User Manual

Page 112

background image

15. In Tera Term, select Control > Macro and then navigate to the c:\tftp directory. Open

EQ2_uboot_upgrade.ttl and follow the macro instructions.

Note:

The macro should reset and re-boot the E-QUE card (MK2) automatically. However, if it does
not, you may have to reset the E-QUE card (MK2) using the reset button on the front. The
reboot should be seen on the serial console. This reset is essential, as it permits Term Term
to interrupt the boot process.

16. If the reset is successful, the following dialog is displayed:

Figure 74: E-QUE (MK2) successful reset dialog

To continue, click OK.

Note:

If the reset and reboot is not successful, the following error message is displayed:

Figure 75: E-QUE (MK2) reset error message

If you receive this message, you are advised to repeat the procedure from Step 6.

17. The boot countdown appears again on the serial console. Tera Term recognizes that the card

has rebooted and you are asked to enter the following information to enable the download:

a. Enter an IP address for the E-QUE card. This address must be in the same range

as your PC IP address (for example, 192.168.42.5).

b. Enter your PC IP address (for example,192.168.42.1).

c. Enter the file name of the E-QUE card application code (firmware) (for example,

eque_release_image-3.16.5.0).

d. Enter the Gateway IP address or accept the default (10.50.16.1).

e. Enter the Subnet Mask or accept the default (255.255.255.0).

105

Eclipse HX Upgrade Guide

This manual is related to the following products: