13.2 Upgrading panel application code manually
The application code for most panels can be upgraded manually either by re-programming the PROM
or by directly connecting the panel to a PC. Before attempting any upgrade, ensure that anti-static
precautions are taken, as Eclipse HX devices are sensitive to static discharges.
Observe all electrical shock hazard warning and precautions for handling
electrostatic sensitive devices
Tip:
For help with selecting the other procedures you require for upgrading to Eclipse HX v7.5 see the
quick reference procedures tables in 2 Selecting Upgrade Procedures.
13.2.1
Cabling for I-Series upgrades
The convertor cable connects from a serial port on the PC, routes through an RS-232 to RS-422
adapter and connects to the expansion out RJ-45 port and the I-Series or the expansion in RJ-45 port
of the E-Station using separate CAT5 cables.
Figure 85
Figure 86: Example converter cable