4. From the Tera Term main screen select Setup > Serial port….
The serial port setup screen should now be visible. Configure Tera Term with the following
settings:
Field
Setting
Baud
19200
Data
8 bit
Parity
None
Stop
1 bit
Flow Control
None
Table 37: Serial port setup screen settings
Note:
Do not configure (ignore) the Transmit delay settings.
Click OK.
5. Power up the I-Series panel into maintenance mode by first holding in the recessed button
found on the rear panel during a simultaneous AC power up.
The reset button must be held in until all front panel keys turn
bright red
and the front panel
display modules show the message Display Module Test’, Press All Buttons 3x.
Tip:
If the recessed button cannot easily be accessed, use a bent paper clip or small flat
blade screwdriver to press the button in.
Figure 91: Module display message