beautypg.com

Clear-Com HX System Frames User Manual

Page 58

background image

6.4.3 Upgrading the Eclipse HX-PiCo application code using

Tera Term

To upgrade the Eclipse HX-PiCo application code using Tera Term:

1. Ensure that you have the following equipment:

Required equipment

Description / comments

PC with either a serial port
connection or USB-to-serial port
adaptor

If using a USB-to-serial port adaptor cable, you must
connect the cable before starting EHX to enable EHX
to detect the USB port as a COM port.

RS232 serial cable

Use a RS232 cable with DB-9 to 3.5mm jack
connectors (a CellCom / FreeSpeak (FSBP)
registration cable

(PD4007Z)).

Tera Term installation

Tera Term must be configured and operational. You
can find the Tera Term application on both of the
Eclipse HX 7.5 DVDs:

Software DVD > 3rd_Party_Software > Teraterm

Hardware DVD > 3rd_Party_Software > Teraterm

The appropriate *.fwr data file for
the Eclipse HX-PiCo application

You can find the *.fwr data file on the software DVD
at:

Software DVD > Eclipse HX-PiCo > xxxxxxZ –
Application
(where xxxxxxZ represents the part
number).

Table 13: Required equipment

2. Install the Tera Term application. Accept all default settings.

51

Eclipse HX Upgrade Guide

This manual is related to the following products: