Clear-Com HX System Frames User Manual
Page 82
5. In the Download window, click Options and ensure that:
• Auto-Disconnect is selected (checked).
• Download File Area has User Area selected (checked).
• The Download File radio button is selected.
6. Select ‘…’ for the User area and select the appropriate MVX code file from the Eclipse HX
v7.5 software DVD. According to your requirements, select either:
• Software DVD > Eclipse HX-Omega-Median-Delta > xxxxxxZ-MVX Boot
Where xxxxxxZ represents the product number. The folder contains the *.mot file
and a Read Me file (*.txt) with version information.
• Software DVD > Eclipse HX-Omega-Median-Delta > xxxxxxZ-MVX Combined
Boot & Application
Where xxxxxxZ represents the product number. The folder contains the *.mot file
and a Read Me file (*.txt) with version information.
7. Upgrade / program the device:
a. Connect the MVX serial cable (
CAB-MVX-48Z) between the COM port on the PC and
CON8 on the MVX-A16 card.
Note:
The MVX connection is polarized to ensure correct connection.
b. On the MVX card, ensure that jumper JP1 is made.
c. Select Program Flash from the Flash Development Toolkit (FDT) program.
d. Confirm that FDT reports the image has been written successfully.
e. Remove the serial cable.
f.
Remove jumper JP1.
Tip:
For the location of connectors and jumpers on the MVX-A16 card, see
Figure 46: MVX-A16 card: J1, CON8.
8. Repeat for Step 7 for all other MVX-A16 cards in the system.
Important note:
If the MVX card fails to upgrade, press the Reset button on the front of the card, and select
Program Flash from the FDT again.
If you are using a USB-to-serial adaptor, the adaptor may have to be unplugged and re-
plugged to enable the upgrade to start on some computers. If you are running the EHX
application, ensure that EHX is configured for Ethernet and not serial connection.
75
Eclipse HX Upgrade Guide