6 upgrading the e-que card (mk2) boot rom, Upgrading the e-que card (mk2) boot rom, 6 upgrading the e-que card (mk2) – Clear-Com HX System Frames User Manual
Page 108: Boot rom )
3. Program the PROM device with the appropriate file, according to the instructions for the
PROM programmer being used.
Note:
The load address for the S record is 0xFFF00000.
4. Confirm that the checksum of the programmed device matches that detailed in the Eclipse HX
Release Notes.
5. Remove the existing PROM device from the configuration card.
6. Insert the newly programmed PROM device taking care to ensure the correct polarity of the
device.
Observe all electrical shock hazard warning and precautions for handling
electrostatic sensitive devices
9.6 Upgrading the E-QUE card (MK2) boot ROM
Only upgrade the E-QUE (MK2) boot ROM after the main E-QUE application code has been
upgraded.
Note:
The procedure below is for E-QUE (MK2) cards only. To upgrade the PROM of an E-QUE card
(MK2), see 9.5 Upgrading the E-QUE card (MK1) boot ROM.
To upgrade the E-QUE (MK2) boot PROM:
1. Ensure that you have the following equipment:
Required equipment
Description / comments
Tera Term software
Tera Term must be configured and operational. You can
find the Tera Term application on both of the Eclipse HX
7.5 DVDs:
Software DVD > 3rd_Party_Software > Teraterm
Hardware DVD > 3rd_Party_Software > Teraterm
TFTP Server software
-
MVX Serial cable (CAB-MVX-
48Z)
See Figure 55: MVX-A16 serial cable (CAB-MVX-48Z)
Ethernet crossover cable
-
Small reset tool
For example, a bent paper clip
Table 29: Required equipment
101
Eclipse HX Upgrade Guide