beautypg.com

At+ifc, Tc63 at command set – Siemens TC63 User Manual

Page 96

background image

TC63 AT Command Set

4.7 AT+IFC

s

TC63_ATC_V00.490

Page 96 of 501

5/24/05

Confidential / Draft - Do not copy

4.7

AT+IFC Set Flow Control separately for data directions

The command

AT+IFC

can be used to set or query the data flow control separately for each data direction. In

contrast to this, flow control settings made with

AT\Q

are valid in both data directions.

Syntax

Parameter Description

Specifies the method used by the TE when receiving data from the TA.
[0]

none

1

XON/XOFF, terminate flow control in the Cellular Engine

2

RTS line

3

XON/XOFF, evaluate flow control in the Cellular Engine and pass it through

(over the air) to the opposite TE

Specifies the method used by the TA when receiving data from the TE.
[0]

none

1

XON/XOFF

2

CTS line

Test Command

AT+IFC=?

Response(s)

+IFC:

(list of supported

s), (list of supported

s)

OK

Read Command

AT+IFC?

Response(s)

+IFC:

,

OK

Write Command

AT+IFC=

,

Response(s)

OK

ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

V.250

!

%

%

!

§

§

§

!

%

!

(num)(&W)

(num)(&W)