18.12 AT^SNFM

s

TC63_ATC_V00.490

Page 423 of 501

5/24/05

Confidential / Draft - Do not copy

18.12

AT^SNFM Set microphone audio path and power supply

The

AT^SNFM

read command returns the microphone mute and supply voltage status.

The

AT^SNFM

write command can be used to switch the microphone's audio path (muted / not muted) or to con-

trol the power supply of the VMIC line for the two microphone inputs.

The microphone can be muted or activated by changing

in all audio modes (1 to 6) and during a

voice call only. As an alternative, you can use the

AT+CMUT

command to mute the microphone.

Syntax

Parameter Description

Microphone mute control parameter.

Evaluated during voice calls and if

is omitted only, e.g.

AT^SNFM

=1.

Command does not depend on audio mode.
0

Mutes the microphone.

1

(P)

Activates the microphone.

Microphone supply voltage control parameter. Controls the power supply VMIC of the two microphone inputs.

CME error is given if

is not omitted. Enter for example

AT^SNFM

=,1 or

AT^SNFM

=,2.

0

Supply voltage is always switched off.

1

Supply voltage is always switched on.

2

(P)

Supply voltage state during voice calls is controlled by the ME. Actual value is

determined by parameter data set of the selected audio mode.

Test Command

AT^SNFM=?

Response(s)

^SNFM:

(list of supported

s) , (list of supported

s)

OK

Read Command

AT^SNFM?

Response(s)

^SNFM:

,

OK

Write Command

AT^SNFM=

[

][,

]

Response(s)

OK

ERROR

+CME ERROR:

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

!

%

%

%

%

%

%

!

%

!

(num)

(num)