Conparmvalue-alphabet, Conparmvalue, R to – Siemens TC63 User Manual
Page 239: Conparmvalue-con, Type, Alphabet, Conparmvalue-dat, Arate, Datatype, Tc63 at command set
TC63 AT Command Set
10.1 AT^SICS
s
TC63_ATC_V00.490
Page 239 of 501
5/24/05
Confidential / Draft - Do not copy
uses dynamic DNS assignment. Any other address means that the Primary
DNS is manually set.
The default value applies automatically if no other address is set. Note that the
read command only returns a manually configured IP address, while
the value "0.0.0.0" is not indicated at all, no matter whether assumed by default
or explicitly specified.
“dns2“
Secondary DNS server address (IP address in dotted-four-byte format).
If "dns1" = "0.0.0.0" this setting will be ignored. Otherwise this value can be
used to manually configure an alternate server for the DNS1.
If "dns1" is not equal "0.0.0.0" and no "dns2" address is given, then
"dns2"="0.0.0.0" will be assumed automatically. The
read command
only returns a manually configured IP address, while the value "0.0.0.0" is not
indicated at all, no matter whether assumed by default or explicitly specified.
Parameter value; type and supported content depend on related
.
Supported connection type values in
for
value "conType".
“CSD“
Circuit-switched data call.
“GPRS0“
GPRS connection.
Settings of GPRS related commands are not used, e.g.
. When a
service based on a GPRS connection profile is started after entering
TC63 automatically tries to attach to the GPRS. Yet, the only exception is
which can be used any time to detach from the GPRS and, and thus
disconnect the bearer opened with
“none“
Clears the connection profile.
Character set selectable with
value "alphabet".
[“0“]
Character set determined with
applies.
“1“
International Reference Alphabet (IRA, seven bit ASCII) applies.
Supported data rate values in
value "dataRate".
“0“
14.4 KBaud
[“1“]
9.6 KBaud
Supported data call type values in
value "dataType".
“0“
ISDN
[“1“]
Analog
(str)
(str)
(str)
(str)
(str)