TC63 AT Command Set
10.1 AT^SICS
s
TC63_ATC_V00.490
Page 237 of 501
5/24/05
Confidential / Draft - Do not copy
10.1
AT^SICS Internet Connection Setup Profile
serves to create and edit Internet connection profiles. A connection profile can be assigned to one or
more service profiles defined with
, and thus, determines which type of connection is to be established
when opening a service profile with
The
read command requests the current settings of all Internet connection profiles. One line is issued
for every possible parameter of a given
"conType" value.
The
write command specifies all parameters of a connection profile identified by
At first the type of Internet connection needs to be selected via
value "conType". This deter-
mines the applicability of all other
values related to this "conType" and automatically sets their
defaults. An exception is the
which can be set before or after selecting "con-
Type". To change the settings the write command needs to be executed for each single
All profile parameters set with
are volatile. Therefore, the best practice is to use scripts and let the host
application handle the required AT commands.
Table 10.1: Applicability of
values
Syntax
value
CSD
GPRS0
"conType"
mandatory
mandatory
"user"
optional
optional
"passwd"
optional
optional
"apn"
ø
mandatory
"inactTO"
optional
optional
"calledNum"
mandatory
ø
"dataRate"
mandatory
ø
"dataType"
mandatory
ø
"authMode"
mandatory
mandatory
"dns1"
optional
optional
"dns2"
optional
optional
"alphabet"
optional
optional
Test Command
AT^SICS=?
Response(s)
OK
Read Command
AT^SICS?
Response(s)
OK
Write Command
AT^SICS=
Response(s)
OK