TC63 AT Command Set

5.7 AT^SPWD

s

TC63_ATC_V00.490

Page 128 of 501

5/24/05

Confidential / Draft - Do not copy

5.7

AT^SPWD Change Password

The

AT^SPWD

command comprises all functions of the

AT+CPWD

command. Apart from the different prefixes

"^SPWD" and "+CPWD", the major difference is that the

list of

AT^SPWD

includes the additional

"CM" password dedicated to the Customer SIM Lock. Set with the command

AT^SCSL

, this type of lock allows

the application manufacturer to lock a mobile to specific operators.

The Customer SIM Lock feature is designed to be configurable during the production of the mobile application.

Therefore, to program the "CM" password, the

AT^SPWD

write command can be used no matter whether the SIM

is inserted or PIN authentication has been done. Opposite to that, passwords for all other facilities can only be

edited if the SIM is present and PIN authentication completed.

IMPORTANT: Please note that, even though there is no need for a factory set Customer SIM Lock, you are

strongly advised to specify at least a "CM" password, avoiding that end users ever have a chance to activate this

lock type.

Each password is a string of digits the length of which varies with the associated facility. The test command

returns a list of pairs which represent the available facilities and the maximum length of the associated password.

See also AT commands

AT+CLCK

and

AT^SLCK

as well as

AT^SCSL

for more detail on the various lock features.

Syntax

Test Command

AT^SPWD=?

Response(s)

^SPWD:

list of supported (

,

)

OK

Write Command

AT^SPWD=

[,

][,

]

Response(s)

New password has been registered for the facility lock function.
OK
If parameter

was not correct:

+CME ERROR 16 (+CME ERROR: incorrect password)
If the password for the selected

has been invalidated due to too many failed attempts:

+CME ERROR ...
In case of trying to set a "CM" password although another type of factory set SIM lock is already active:
+CME ERROR: Operation not supported.
If error is related to ME functionality:
+CME ERROR

PIN