Page 75: 2 display, The following two sim elementary, Tc63 at command set

background image

TC63 AT Command Set

3.3 AT^SIND

s

TC63_ATC_V00.490

Page 75 of 501

5/24/05

Confidential / Draft - Do not copy

manual network selection fails and the module automatically falls back to the

previous network the NITZ values cannot be recalled. Nevertheless an indi-

cated time zone is valid until a new MMI/GMMI will trigger another NITZ indi-

cation.

“band“

Currently selected frequency band or band combination.

Integer type value in the range stated above for the corresponding

.

Notes specific to the EONS feature:

If the indicator is "eons", the

is a type associated to the operator name according to GSM 22.101

[25]

. This type depends on the source of the operator name.

Priority of types associated to the operator names is defined as follows (the type listed first has the highest pri-

ority). If a type cannot be indicated the next one will be used.

The name information received by the NITZ service (type 3) will be saved in the non-volatile RAM. It replaces

the operator name of the registered PLMN (type 4) or its numeric form (type 5) stored in the ME. However, when

after restart the ME registers to another PLMN that is not equal to the saved NITZ name information, the NITZ

name information must be invalidated.

If the type is 2, 4 or 5,

AT+COPS

with the appropriate

displays the same operator name.

0

Indicator is deregistered, i.e. no such indicator event report (URC) will be

issued.

=0 is power-up and factory default of indicators defined by

AT^SIND

only.

1

Indicator is registered.
• Indicator event reports are controlled via

AT+CMER

.

• All indicators can be registered or deregistered via

AT^SIND

, but different

default settings apply: Power-up and factory default of the indicators sup-

ported by

AT+CIND

is

=1, while, as stated above, indicators defined

by

AT^SIND

only are set to

=0.

2

Query the registration status and the current value of a single indicator type.

ADN phonebook record number on the SIM.

1...14 Identical with

of

AT^SCFG

. The value indicates the band(s) cur-

rently available for network selection, depending on the network config-

uration either a single band or a dualband combination. The URC

appears whenever the status of the currently available band(s)

changes, for example after using the

AT^SCFG

command to change

the "Radio/Band" parameters

or

. Please see

AT^SCFG

for further detail about the feature "Radio/Band" selection.

(num)

0

Not registered.

1

EF-OPL and EF-PNN (alphanumeric format, can contain up to 24 characters.)

2

Operator Name String in long and short format according to Common PCN

Handset Specification (CPHS)

[26]

(alphanumeric format, can contain up to 16

characters).

3

Name information received by the NITZ service long and short form (alphanu-

meric format, can contain up to 16 characters). The short form will be displayed

only if EF

OPShort

from CPHS is available.

4

Any operator name stored internal to the ME (alphanumeric format, can con-

tain up to 16 characters).

5

Broadcast MCC-MNC (numeric format which consists of a 3-digit country code

plus a 2- or 3-digit network code).

(num)

(num)