7.5 ATD>
s
TC63_ATC_V00.490
Page 146 of 501
5/24/05
Confidential / Draft - Do not copy
7.5
ATD>
number
Syntax
Command Description
TA attempts to set up an outgoing call to the stored number. The termination character ";" is mandatory since
dialing from a phonebook is only supported for voice calls and for sending *# codes of Supplementary Services
or other functions.
Parameter Description
Integer type memory location in the range of locations available in the selected memory, i.e. the index number
returned by
String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called party)
i Deactivates CLIR (enables presentation of own phone number to called party)
Notes
• This command may be aborted generally by receiving a character during execution. Abortion is not possible
during some states of connection setup such as handshaking.
• The command is not applicable to data calls. Any attempt to dial a data call number from
causes the
result code "NO CARRIER" to appear.
• Parameter
only if no *# code is within the dialing string.
Exec Command
[
];
Response(s)
ERROR
+CME ERROR:
If no dialtone (parameter ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
When TA returns to command mode after call release:
OK
If successfully connected:
OK
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
V.250
%
%
§
%
%
§
§
!
!
!
(num)