beautypg.com

Serial interface control commands, 1 at\q flow control, At\q flow control – Siemens TC63 User Manual

Page 89: At\q, L is, 0 wh, Tc63 at command set

background image

TC63 AT Command Set

4. Serial Interface Control Commands

s

TC63_ATC_V00.490

Page 89 of 501

5/24/05

Confidential / Draft - Do not copy

4.

Serial Interface Control Commands

The AT Commands described in this chapter allow the external application to determine various settings related

to the TC63's serial interface.

4.1

AT\Q Flow control

Syntax

Parameter Description

[0]

(&F)

Disable flow control

1

XON/XOFF software flow control

2

Only CTS by DCE (TA)

3

RTS/CTS hardware flow control

Recommended for the following procedures: incoming or outgoing data calls,

fax calls, MUX mode.

Often, the initialization routine of Fax programs includes enabling RTS/CTS

handshake, eliminating the need to issue

AT\Q

3 once again.

Notes

• When using XON/XOFF flow control (

AT\Q

1) in online mode,

+++

should not be used while the data trans-

mission is paused with XOFF. Before entering the command mode with

+++

the paused transmission should

be resumed using the XON character.

• For compatibility reasons, the

AT\Q

command can be used in Multiplex mode, though the settings will not

take effect. However, be aware that whenever you use the

AT\Q

write command in Multiplex mode and then

save the current configuration to the user profile with

AT&W

, the changed

AT\Q

setting will become active after

restart.

• Flow control can also be set using

AT+IFC

.

Exec Command

AT\Q

[

]

Response(s)

OK
If RTS/CTS flow control is not supported by interface and

is 2 or 3:

ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

!

%

%

!

§

§

§

!

%

!

(num)(&W)(&V)