Tc63 at command set – Siemens TC63 User Manual
Page 70
TC63 AT Command Set
3.2 AT+CIND
s
TC63_ATC_V00.490
Page 70 of 501
5/24/05
Confidential / Draft - Do not copy
Notes
• Due to its restrictive value range, indicator "call" does not clearly reflect specific call states (such as alerting,
active, held etc.), but rather serves to trigger the application to retrieve the new call status from the list of cur-
rent calls with the AT commands
.
• If
setting
="verbose", indicator "call" will be issued also when a traffic channel is estab-
lished, or when a call enters states "terminating" or "dropped" (see
In these cases, the relevant information about the cause of the display is available only from AT command
Examples
EXAMPLE 1
EXAMPLE 2
Deactivation of indicator "sounder" via
EXAMPLE 3
Deactivation of indicator "sounder" via
^SYSSTART
AT+CPIN=9999
OK
AT+CIND?
+CIND: 5,0,1,0,0,0,0,0
The battery is either full or no battery is connected to the ME. The bit
error rate of the signal quality is not available (since there is no call in
progress). The ME is registered to its home network.
OK
AT+CMER=2,0,0,2
Now activate the Indicator Event Report with
OK
+CIEV: battchg,5
+CIEV: signal,0
+CIEV: service,1
+CIEV: sounder,0
+CIEV: message,0
+CIEV: call,0
+CIEV: roam,0
+CIEV: smsfull,0
+CIEV: rssi,5
Full receive signal strength.
ATD0123456;
Make a call.
OK
+CIEV: sounder,1
A set of "
" URCs is received.
+CIEV: call,1
+CIEV: sounder,0
+CIEV: call,0
Called party hangs up.
NO CARRIER
AT+CIND=,,,0,,0
Deregister the indicators "sounder" and "call".
OK
ATD0123456;
Dial the same call.
OK
This time, no URCs are displayed.
NO CARRIER
Called party hangs up.
AT+CIND?
Query the current status of indicators.
+CIND: 5,0,1,0,1,0,0,0,4
OK
AT+CIND=,,,0
To deactivate indicator "sounder" (= fourth item in list of indicators).
OK
AT^SIND="sounder",0
To deactivate indicator "sounder".
^SIND: sounder,0,0
OK