beautypg.com

Tc63 at command set – Siemens TC63 User Manual

Page 444

background image

TC63 AT Command Set

19.5 AT^SCTM

s

TC63_ATC_V00.490

Page 444 of 501

5/24/05

Confidential / Draft - Do not copy

19.5

AT^SCTM Set critical operating temperature presentation mode
or query temperature

Use this command to monitor the temperature range of the module and the battery. The write command enables

or disables the presentation of URCs to report critical temperature limits.

CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs

can be always displayed regardless of the selected mode

.

Syntax

Unsolicited Result Codes

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when

it is back to normal.

^SCTM_A:

for battery temperature

URC 2

^SCTM_B:

for module (board) temperature

Test Command

AT^SCTM=?

Response(s)

^SCTM:

(list of supported

s)

OK

Read Command

AT^SCTM?

Response(s)

^SCTM:

,

OK

ERROR

+CME ERROR

Write Command

AT^SCTM=

Response(s)

OK

ERROR

+CME ERROR

Reference(s)