7 at^sspi serial protocol interface, Tc63 at command set – Siemens TC63 User Manual
Page 450
TC63 AT Command Set
19.7 AT^SSPI
s
TC63_ATC_V00.490
Page 450 of 501
5/24/05
Confidential / Draft - Do not copy
19.7
AT^SSPI Serial Protocol Interface
The
command enables the module to be connected to external I²C devices. The I²C datastream is
mapped through an internal I²C driver to and from an ASCII hex protocol which can be exchanged with an exter-
nal application via V24.
The
write command configures and activates the I²C interface and changes from command mode into
data mode. All values must be given in hexadecimal format (0 - 9, A - F) without "0x". For details on data mode
Transmitting Data over AT Interface
.
Syntax
Parameter Description
Parameter returned by the
? read command.
Indicates whether or not the I²C channel is used. When the channel is open and the ME is in data mode, the
read command can only be used if one of the remaining interfaces is available. For example, when the channel
was opened on ASC0, you can use ASC1, MUX channels or USB to check the status.
[0]
(&F)
Not connected (channel closed). All following parameters are the factory set-
=0,0010,0000,0000.
1
Connected (channel open, ME in data mode). All following parameters are the
values currently used, for example
=1,0010,FFFF,FFFF.
Parameter
is a 16 bit word which contains four subparameters to control the follow-
ing functions:
Test Command
AT^SSPI=?
Response(s)
^SSPI:
(list of supported
s), (list of supported
s)
OK
Read Command
AT^SSPI?
Response(s)
,
OK
ERROR
+CME ERROR:
Write Command
AT^SSPI=
[,
]]]
Response(s)
CONNECT
(indicates that ME has entered data mode)
ERROR
+CME ERROR:
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
!
%
%
%
%
%
%
!
%
%
(num)
(num)