Sctm, Tc63 at command set – Siemens TC63 User Manual
Page 445
TC63 AT Command Set
19.5 AT^SCTM
s
TC63_ATC_V00.490
Page 445 of 501
5/24/05
Confidential / Draft - Do not copy
Command Description
The read command returns:
• the URC presentation mode
• information about the current temperature range of the module
Please note that the Read command does not indicate the temperature range of the battery. The battery temper-
ature can only be reported by an Unsolicited Result Code.
Select
to enable or disable the presentation of the URCs. Please note that the setting will not be stored upon
Power Down, i.e. after restart or reset, the default
=0 will be restored. To benefit from the URCs
=1 needs
to be selected every time you reboot the GSM engine.
Parameter Description
0
(&F)(P)
Presentation of URCs is disabled (except for
equal to -2 or +2).
1
Presentation of URCs is enabled.
-2
Below lowest temperature limit (causes immediate switch-off)
-1
Below low temperature alert limit
0
Normal operating temperature
1
Above upper temperature alert limit
2
Above uppermost temperature limit (causes immediate switch-off)
Notes
• Please refer to the "Hardware Interface Description" for specifications on critical temperature ranges.
• To avoid damage the module will shut down once the critical temperature is exceeded.
The procedure is equivalent to the power-down initiated with
• URCs indicating the alert level "1" or "-1" are intended to enable the user to take appropriate precautions,
such as protect the module and the battery from exposure to extreme conditions, or save or back up data etc.
The presentation of "1" or "-1" URCs depends on the settings selected with the write command:
If
=0: Presentation is enabled for 15 s time after the module was switched on. After 15 s operation, the
presentation will be disabled, i.e. no URCs will be generated.
If
= 1: Presentation of "1" or "-1" URCs is always enabled.
• Level "2" or "-2" URCs are followed by immediate shutdown. The presentation of these URCs is always
enabled, i.e. they will be output even though the factory setting
=0 was never changed.
• If the temperature limit is exceeded while an emergency call is in progress the engine continues to measure
the temperature and to deliver alert messages, but deactivates the shutdown functionality. Once the call is
terminated full temperature control will be resumed. If the temperature is still out of range ME switches off
immediately.
Examples
EXAMPLE 1
URCs issued when the operating temperature is out of range:
(num)
(num)
^SCTM_A: 1
Caution: Battery close to overtemperature limit.
^SCTM_A: 2
Alert: Battery above overtemperature limit. Engine switches off.
^SCTM_B: 1
Caution: Engine close to overtemperature limit.
^SCTM_B: 2
Alert: Engine is above overtemperature limit and switches off.
^SCTM_A: -1
Caution: Battery close to undertemperature limit.
^SCTM_A: -2
Alert: Battery below undertemperature limit. Engine switches off.
^SCTM_B: -1
Caution: Engine close to undertemperature limit.
^SCTM_B: -2
Alert: Engine is below undertemperature limit and switches off.