Text, Tlength, Type – Siemens TC63 User Manual
Page 399: Nlength, Maxloc, Tc63 at command set
TC63 AT Command Set
17.5 AT+CPBW
s
TC63_ATC_V00.490
Page 399 of 501
5/24/05
Confidential / Draft - Do not copy
Type of address octet, which defines the used type of number (ton) and the numbering plan identification (npi).
Please consider that for types other than 129 or 145 dialing from phonebook with
is, depending
on the network, not always possible (refer GSM 04.08 subclause 10.5.4.7 for details).
contains a leading "+"
=145
(international) is used.
Supported values are:
145
Dialing string
includes international access code character "+"
161
National number. The network support for this type is optional.
209
Dialing string
will be saved as ASCII string.
This is the default value, if
is not specified explicitly and characters
other than "*", "#" or "+" are included in
.
Note that phonebook entries saved with this type cannot be dialed.
255
Dialing string
is a command to control a Supplementary Service,
i.e. "*", "#" codes are contained. Network support of this type is optional.
129
Unknown number. If
is unknown and the
contains a lead-
ing "+", then this sign is removed.
Text assigned to the phone number. The maximum length of this parameter is given in the test command
. When using an ASCII terminal, characters which are coded differently in ASCII and GSM
have to be entered via escape sequences as described in Section
.
Maximum number of locations supported by the currently selected storage. For phonebooks located on SIM,
this value varies depending on the SIM card. See
Maximum length of phone number for "normal" locations. Depending on the storage, a limited number of loca-
tions with extended memory is available per phonebook. These locations allow storing numbers with twice the
standard length, which is 2*
digits for normal numbers, but only
digits for numbers
saved with parameter
= 209. If all extended locations of the selected phonebook are used up, then any
attempt to write a number which requires extended memory will be denied with CME ERROR 260: INVALID
DIAL STRING.
assigned to the telephone number. The value indicated by the test command is
given in octets. If the
string is given in GSM characters, each character corresponds to one octet. If the
string is given in UCS2, the maximum number of characters depends on the coding scheme used for
the alpha field of the SIM. In the worst case the number of UCS2 characters is at least one less than half the
number of GSM characters.
For a detailed description please refer to GSM 11.11, Annex B
Note
•
can be used only after the phonebook data from the SIM have been read successfully for the first
time. Reading starts after successful SIM authentication has been performed, and may take up to 30 seconds
depending on the SIM used. While the initial read process is in progress, an attempt to use any of the phone-
book commands will result in "+CME Error: 14" (SIM busy).
We recommend to take advantage of the "
" URC. If enabled with
, this URC notifies
the user when SIM data are accessible after SIM PIN authentication. The URC will be delivered once the ME
has completed reading data from the SIM card.
(num)
(str)(+CSCS)
(num)
(num)
(num)