beautypg.com

How to load panel program (firmware updates) – Interlogix Topaz User Manual User Manual

Page 107

background image

Chapter 5

Control

89

How to download data to a selected panel using a dial-up connection

To download to a dial-up panel:

1. Scroll through the list of pre-configured Dial-up Panels and select the panel to download to by

clicking on the name in the list so that it is highlighted.

2. Next select one of the four download options:

Download & Hang Up

Download & Stay Connected

Break Connection - Hang Up

Initialize - Test Modem & Serial Port

The desired option can be selected by clicking on the white circle to the right of the
option. This places a small black dot in the circle indicating the option is selected.

3. Once the panel or port name is highlighted and the option is selected, click Call located to the

left of the Dial-up Panels list to start the requested communication function.

A message “Operation Complete” displays.

How to load panel program (firmware updates)

Prerequisite:

Panel firmware versions 7.07.02 and newer require:

Topaz software version 1.4.6 or later

Panel firmware version 5.85.00 or later

Note: If the version of your panel firmware is earlier than 5.85.00, you must first upgrade to version 5.85.00 (located in

Topaz CD\Firmware\Beta) and then again to the latest version (located in Topaz CD\firmware\)

1. At the bottom of the screen, in the Load Panel Program section, select the panel you wish to

upgrade from the Field Panel list.

2. In the PROM File Name field, enter the update firmware file name using one of the following

methods:

a. Type the PROM file name. When typing the PROM File Name in the field you must enter

the entire file path, for example, C:\acux070702.s19

b. Click Browse and navigate to the Topaz CD\Firmware\ folder to locate the newest

firmware file. Click Open.

Note: Firmware can only be upgraded from the server. The PROM File can be received in a number of ways,

e.g., floppy disk, E-mail, or CD. Once you receive the file, we recommend that you copy the file to the
hard drive of the server and then reference the updated file from the hard drive. Running an update from
the floppy drive can be VERY slow.

It is also recommended, after updating one panel you check all the features in the updated panel to make
sure that it is functioning properly then continue updating the other panels on your system one at a time.

3. Click Load located to the left of the Field Panels list to start the program loading. A message

“Operation Complete” displays.