Figure 2-71 Default setting of DIP switches

on

1

2

3

4

5

6

7

8

Description of DIP switch settings is given in the following table:

Table 2-45 Description of DIP switch settings of SIC-ERRI/SIC-1E1-F

DIP

Description

Configuration of

75-ohm impedance

Configuration of

120-ohm impedance

1BIT ON

OFF

2BIT ON

OFF

3BIT ON

OFF

4BIT ON

OFF

5BIT

75-ohm/120-ohm
selection switch

ON OFF

6BIT

RxRing grounding mode
selection switch

OFF: RxRing is grounded
via capacitance.
ON: RxRing is grounded
directly.

7BIT

RxShield grounding
mode selection switch

ON: RxShield is
grounded.
OFF: RxShield is not
grounded.

8BIT

SxShield grounding
mode selection switch

OFF: RxShield is
grounded via
capacitance
ON: RxShield is
grounded directly.

z

It is recommended to select the DIP switch in this way: when connecting 75-ohm cable, flip BIT1-8
to ON, and when connecting 120-ohm cable, flip BIT1-8 to OFF.

z

By default, all of the DIP switches are factory-configured to ON, that is, the impedance of E1
interface is 75-ohm.