4-38
Figure 4-44 FIC-8E1 (120-ohm) panel
Figure 4-45 FIC-8E1 (75-ohm) panel
The following table describes the LEDs on the module panels:
Table 4-32 LEDs on the FIC-8E1/FIC-8E1-F panels
LED
Description
LINK
z
OFF means no link is present;
z
ON means a link is present.
ACTIVE
z
OFF means no data is being transmitted or received.
z
ON means data is being transmitted and/or received.
Interface cable
The FIC-8E1/FIC-8E1-F module provides eight E1 ports and adopts a 120-ohm or a 75-ohm 8E1
conversion cable. The two types of cables look similar. Both of them have a DB-68 connector at one
end for connecting the router. At the other end, however, the 75-ohm 8E1 conversion cable provides 16
coaxial cable connectors; and the 120-ohm 8E1 conversion cable provides eight twisted pair cable
connectors, as shown in the following figures: