beautypg.com

Mim-8t1/mim-8t1-f, Introduction, Interface attributes – H3C Technologies H3C MSR 50 User Manual

Page 149

background image

3-45

Figure 3-52 Extending a T1 cable

Router

DDN, etc

RJ45

Network interface connector

RJ45

Straight-through network cable

RJ45

shielding network cable)

T1 cable (100-ohm straight-through

Step3 Check the behavior of the LINK LED on the MIM-T1 or MIM-T1-F panel. It is OFF when the line is

faulty and signal is out of synchronization. In this case, check the link.

MIM-8T1/MIM-8T1-F

Introduction

1) MIM-8T1

MIM-8T1, the 8-port channelized T1/PRI interface module, transmits, receives, and processes eight
channels of T1 data traffic. In addition, you can use the module for other purposes, such as CT1 access
and the ISDN PRI function.

2) MIM-8T1-F

MIM-8T1-F, the 8-port fractional T1 interface module is different from the 8T1 module in the sense that:

z

The FT1 operating mode supported by the MIM-8T1-F module allows only one n × 64 kbps or n ×
56 kbps bundle to be formed on each interface, where n = 1 to 24. However, the MIM-8T1 module
allows arbitrary grouping of 24 channels and therefore multiple bundles.

z

The MIM-8T1-F module does not support PRI mode.

Given a MIM-8T1 module, the system automatically creates a serial interface for each timeslot bundle
formed on a controller T1 interface.

Interface attributes

The interface attributes of the MIM-8T1 and the MIM-8T1-F are given in the following table:

Table 3-38 Interface attributes of the MIM-8T1 and the MIM-8T1-F

Attribute

Description

Connector RJ-45

Number of connectors

1

Interface standard

z

G.703/T1 102

z

G.704

z

AT&T TR 54016

z

AT&T TR 62411

z

ANSI T1.403

This manual is related to the following products: