beautypg.com

Interface cable, Connecting the interface cable – H3C Technologies H3C MSR 50 User Manual

Page 189

background image

3-85

The MIM-2VT1 module is 1U in height, occupying two slots.

Interface cable

The interface cable of MIM-2VT1 is a standard 100-ohm shielding cable. The connectors on the two
ends are RJ-45 connectors. The following figure illustrates this type of cable.

Figure 3-103 T1 cable

For the pinouts of T1 cables, see Low-End and Mid-Range Series Routers Cable Manual.

The corresponding cables are not included in the standard shipment package of MIM-2VT1. Please
order them together with MIM-2VT1. By default, they are not supplied.

Connecting the interface cable

z

Connect a cable to the port with the correct mark. Misplugging is prone to impair the module and
even damage the router.

z

When using T1 cable outdoors, you are recommended to install a special lightning arrester on the
input end of the cable in order to avoid lightning more effectively.

If the MIM has been properly installed, follow these steps to connect the cable:

Step1 Plug one end of T1 cable into the RJ-45 connector of MIM-2VT1.

Step2 Connect the other end of T1 cable to the peer device;

Step3 Check the status of LINK LED on the MIM-2VT1 panel: OFF means the link is not connected. In the

latter case, check the line.

This manual is related to the following products: