Interface leds, Interface optical fiber, Pos (sdh/sonet) interface module – H3C Technologies H3C MSR 50 User Manual
Page 216: Fic-1pos, Introduction
4-21
Interface LEDs
The following figure illustrates the FIC-1ATM-OC3 panel.
Figure 4-24 FIC-1ATM-OC3 panel
The following table describes the LEDs on the FIC-1ATM-OC3 panel.
Table 4-20 Description of the LEDs on the FIC-1ATM-OC3 panel
LED
Description
LINK/ACT
z
ON means carrier signal has been received.
z
Blinking means data is being received or/and transmitted.
z
OFF means no carrier signal has been received.
LP/AL
z
ON means the interface is in a loopback.
z
Blinking means an AIS, LFA, or RAI alarm signal is present.
z
OFF means no loopback or alarm is present.
Note:
LFA = Loss of frame alignment; AIS = Alarm indication signal; RAI = Remote alarm indication.
Interface optical fiber
Choose an optical fiber cable appropriate to the FIC-1ATM-OC3 for installation.
Laser danger! Do not directly stare at the optical fiber connector connected with the laser, in case of the
injury that may cause to your eyes.
POS (SDH/SONET) Interface Module
z
FIC-1POS
FIC-1POS
Introduction
FIC-1POS, the 1-port SDH/SONET interface module, supports interface rates up to 155.52 Mbps
(STM-1/OC-3).
The FIC-1POS uses the protocols such as PPP, Frame Relay and HDLC at the data link layer and IP at
the network layer. It allows direct transmission of packets over SONET/SDH. It supports:
z
Four types of SFP: multi-mode short-haul (1310 nm), single mode medium-haul (1310 nm), single
mode long-haul (1310 nm), and single-mode ultra-long haul (1550 nm).