beautypg.com

Introduction, Interface attributes, Interface leds – H3C Technologies H3C MSR 50 User Manual

Page 235

background image

4-40

Step4 Power on the router. Check the behavior of the LINK LED on the module panel: OFF means fault has

occurred on the line and signal is out of synchronization. Check the line status.

FIC-1T1/FIC-2T1/FIC-4T1 and FIC-1T1-F/FIC-2T1-F/FIC-4T1-F

Introduction

1) FIC-1T1/FIC-2T1/FIC-4T1

FIC-1T1/FIC-2T1/FIC-4T1, the 1-/2-/4-port channelized T1/PRI interface module, transmits, receives,
and processes T1 data traffic. In addition, you can use the module for other purposes, such as CT1
access and the ISDN PRI function.

2) FIC-1T1-F/FIC-2T1-F/FIC-4T1-F

FIC-1T1-F/FIC-2T1-F/FIC-4T1-F, the 1-/2-4-port fractional T1 interface module, differs from the
FIC-1T1/FIC-2T1/FIC-4T1 primarily in the sense that:

z

The FT1 operating mode supported by the T1-F modules allows only one n × 64 kbps or n × 56
kbps bundle to be formed on each interface, where n = 1 to 24. However, a T1 module allows
arbitrary grouping of 24 channels and multiple bundles.

z

The FIC-T1-F modules do not support PRI mode.

Interface attributes

The following table describes the interface attributes of the FIC-T1/FIC-T1-F modules.

Table 4-33 Interface attributes of the FIC-T1/FIC-T1-F modules

Attribute

Description

Connector

RJ-45

Number of connectors

z

1 (FIC-1T1/FIC-1T1-F)

z

2 (FIC-2T1/FIC-2T1-F)

z

4 (FIC-4T1/FIC-4T1-F)

Interface standard

z

G.703/T1 102

z

G.704

z

AT&T TR 54016

z

AT&T TR 62411

z

ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm straight-through shielded cable)

Operating mode

CT1, ISDN PRI (only supported by the FIC-T1 modules)
FT1 (only supported by the FIC-T1-F modules)

Supported service

z

Backup

z

Leased line

z

ISDN PRI (only supported by the FIC-1T1/FIC-2T1/FIC-4T1 module)

Interface LEDs

The following figure illustrates the FIC-1T1 panel.

This manual is related to the following products: