ISDN BRI Interface Module
z
FIC-4BSE
FIC-4BSE
Introduction
FIC-4BSE, the four-port ISDN BRI interface module, transmits, receives, and processes four channels
of ISDN BRI S/T data traffic on ISDN BRI S/T interfaces.
The FIC-4BSE differs from the FIC-4BS only in the way they set matched resistance for an ISDN BRI
S/T interface: the FIC-4BS uses jumpers while the FIC-4BSE uses DIP switches.
The FIC-4BSE can work in dial mode or leased line mode.
Interface attributes
The following table describes the interface attributes of the FIC-4BSE.
Table 4-45 Interface attributes of the FIC-4BSE
Attribute
Description
Connector RJ-45
Number of connectors
4
Cable
ISDN S/T cable
Protocol & standard
ITU-T I.430, Q.921, Q.931
Operating mode
z
ISDN dial-up
z
ISDN leased line
Supported service
z
ISDN
z
ISDN supplementary services
z
Multi-user number
z
Sub-addressing
z
Backup
Jumper settings
The FIC-4BSE uses jumpers to set matched resistance for ISDN BRI S/T interfaces. The use of
100-ohm resistance on an ISDN BRI S/T interface depends on jumper settings. The following figure
shows the jumper settings, where all the ISDN BRI S/T interfaces are using 100-ohm resistance.
Figure 4-65 Jumper settings of the FIC-4BSE (example)
S1
S2
S3
S4
S5
S6
S8
S7
2
3
0
1
The following table describes how to set jumpers.